MO29 Dupont Refrigeration Gas
Approx. Price: Rs 1,350 / Kilogram
pH | Neutral |
Brand | Dupont |
Volatile | 100 % |
Form | Liquefied gas |
Odor | Slight, Ether-like |
Vapour Pressure | 12,200 hPa at 25 Deg C (77 Deg F) |
Density | 1.157 g/cm3 at 25 Deg C (77 Deg F) |
Specific Gravity | 1.15 at 25 Deg C (77 Deg F) |
Water Solubility | 5 g/l at 25 Deg C (77 Deg F) |
Boiling Point | -43 Deg C (-45 Deg F) |
Vapour Density | 3.9 at 25 Deg C (77 Deg F) and 1013 hPa (Air=1.0) |
- Product name: DuPont™ ISCEON® MO29™ refrigerant
- Product Grade/Type: ASHRAE Refrigerant number designation: R-422D
- Tradename/Synonym: Isceon® MO29 R-422D MO29
- MSDS Number: 130000027389
- Product Use: Refrigerant
- Manufacturer: DuPont 1007 Market Street Wilmington, DE 19898
- Product Information: 1-800-441-7515 (outside the U.S. 1-302-774-1000)
- Medical Emergency: 1-800-441-3637 (outside the U.S. 1-302-774-1139)
- Transport Emergency: CHEMTREC: 1-800-424-9300 (outside the U.S. 1-703-527-3887).
Emergency Overview Misuse or intentional inhalation abuse may lead to death without warning. Vapours are heavier than air and can cause suffocation by reducing oxygen available for breathing. Rapid evaporation of the liquid may cause frostbite.
- Skin: Contact with liquid or refrigerated gas can cause cold burns and frostbite.
- Eyes: Contact with liquid or refrigerated gas can cause cold burns and frostbite.
- Inhalation: Misuse or intentional inhalation abuse may cause death without warning symptoms, due to cardiac effects. Other symptoms potentially related to misuse or inhalation abuse are: Anaesthetic effects, Light-headedness, dizziness, confusion, incoordination, drowsiness, or unconsciousness, irregular heartbeat with a strange sensation in the chest, heart thumping, apprehension, feeling of fainting, dizziness or weakness. Vapours are heavier than air and can cause suffocation by reducing oxygen available for breathing.
- Target Organs Isobutane (<0.1% butadiene): Central nervous system
Carcinogenicity:
None of the components present in this material at concentrations equal to or greater than 0.1% are listed by IARC, NTP, or OSHA, as a carcinogen.
- Skin contact: In case of contact, immediately flush skin with plenty of water for at least 15 minutes. Take off all contaminated clothing immediately. Consult a physician. Wash contaminated clothing before re-use. Treat for frostbite if necessary by gently warming affected area.
- Eye contact: In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Consult a physician if necessary.
- Inhalation: Remove from exposure, lie down. Move to fresh air. Keep patient warm and at rest. Artificial respiration and/or oxygen may be necessary. Consult a physician.
- Ingestion: Is not considered a potential route of exposure.
- General advice: Never give anything by mouth to an unconscious person. When symptoms persist or in all cases of doubt seek medical advice.
- Notes to physician: Because of possible disturbances of cardiac rhythm, catecholamine drugs, such as epinephrine, that may be used in situations of emergency life support should be used with special caution.
Flammable Properties:
- Flash point: does not flash
- Lower explosion limit: Method : None per ASTM E681
- Upper explosion limit: Method : None per ASTM E681
- Fire and Explosion Hazard: Cylinders are equipped with pressure and temperature relief devices, but may still rupture under fire conditions. Decomposition may occur. Contact of welding or soldering torch flame with high concentrations of refrigerant can result in visible changes in the size and colour of the torch flame.
MO59 Dupont Refrigerant Gas
Approx. Price: Rs 1,750 / Kilogram
Specific Name | MO59 |
Brand | Dupont |
Boiling Point | -39 Deg C (1 atm) |
Liquid Density | 1149 kg/m3 at 25 Deg C |
Vapor Pressure | 985 kPa abs at 25 deg C |
Ozone Depletion Potential | 0 CFC-11 = 1.0 |
Global Warming Potential | 2240 CO2 =1 |
Density Satd Vapor | 47.7 kg/m 3 at 25 Deg C |
The use of ISCEON® MO59 in the EU and EEA member countries is regulated under the terms of the Regulation 842/2006 (known as the “F Gas Regulation”), which requires regular leakage testing for systems using the designated substances. ISCEON® MO59 (R417A) is listed in the European Standard EN 378:2008 (Refrigerating and Heat Pump Systems – Safety and Environmental Requirements); Part 4 of this standard relates to retrofit activities.
The following provides a summary of the basic retrofit steps for ISCEON® MO59.
(Detailed discussion of each step is provided in this bulletin.)
- Establish baseline performance with existing refrigerant and check for leaks. (See retrofit checklist (attached))
- Remove all of the old (R22 or other) refrigerant from the system into a recovery cylinder. Weigh the amount removed.
- Where practical replace the filter drier and critical elastomeric seals/gaskets.
- Evacuate system and check for leaks.
- Charge with ISCEON® MO59. • Remove liquid only from charging cylinder. • The initial charge amount should be approximately 85% of the standard charge for R22. The final charge amount is typically approximately 95%.
- Start up system, adjust charge size (unless liquid receiver or TXV present) to achieve optimum superheat.
- Monitor oil levels in compressor, if possible. Add oil as required to maintain proper levels
- Label system showing the refrigerant (and any replacement lubricant) used. Update system log-book.
Like CFCs and HCFCs, ISCEON® 9 Series refrigerants are safe to use when handled properly. However, any refrigerant can cause injury or even death when mishandled. Please review the following guidelines before using any refrigerant.
- Do not work in high concentrations of refrigerant vapors. Always maintain adequate ventilation in the work area. Do not breathe vapors. Do not breathe lubricant mists from leaking systems. Ventilate the area well after any leak before attempting to repair equipment.
- Do not use handheld leak detectors to check for breathable air in enclosed working spaces. These detectors are not designed to determine if the air is safe to breathe. Use oxygen monitors to ensure adequate oxygen is available to sustain life.
- Pay Mode Terms: T/T (Bank Transfer)
- Port of Dispatch: Road
- Delivery Time: IMMEDIATE
Suva 95 Dupont Refrigerant Gas
Approx. Price: Rs 14,500 / Kilogram
Boiling Point | -87.6 Deg C (-125.7 Deg F) |
Vapor Pressure | 36,568 hPa at 10 Deg C (50 Deg F) |
Odor | Slight, Ether-Like |
Specific Gravity | 1.15 at 25 Deg C (77 Deg F) |
Volatile | 100 % |
Brand | Dupont |
- Product name: DuPont™ Suva® 95 refrigerant
- Tradename/Synonym: Suva® 508B R-508B
- Product Grade/Type: ASHRAE Refrigerant number designation: R-508B.
- Product Use: Refrigerant, For professional users only.
- Restrictions on use: Do not use product for anything outside of the above specified uses.
- Manufacturer/Supplier: DuPont 1007 Market Street Wilmington, DE 19898 United States of America.
- Product Information: +1-800-441-7515 (outside the U.S. +1-302-774-1000)
- Medical Emergency: 1-800-441-3637 (outside the U.S. 1-302-774-1139)
- Transport Emergency: CHEMTREC: +1-800-424-9300 (outside the U.S. +1-703-527-3887).
Product hazard category
- Gases under pressure Liquefied gas
- Signal word: Warning
- Hazardous warnings: Contains gas under pressure; may explode if heated.
- Hazardous prevention measures: Protect from sunlight. Store in a well-ventilated place.
- Misuse or intentional inhalation abuse may lead to death without warning. Vapours are heavier than air and can cause suffocation by reducing oxygen available for breathing. Rapid evaporation of the liquid may cause frostbite., May cause cardiac arrhythmia.
- General advice: Never give anything by mouth to an unconscious person. When symptoms persist or in all cases of doubt seek medical advice.
- Inhalation: Remove from exposure, lie down. Move to fresh air. Keep patient warm and at rest. Artificial respiration and/or oxygen may be necessary. Consult a physician.
- Skin contact: In case of contact, immediately flush skin with plenty of water for at least 15 minutes. Take off all contaminated clothing immediately. Consult a physician. Wash contaminated clothing before re-use. Treat for frostbite if necessary by gently warming affected area.
- Eye contact: In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Consult a physician if necessary.
- Ingestion: Is not considered a potential route of exposure.
- Most important symptoms/effects, acute and delayed: Anaesthetic effects Light-headedness irregular heartbeat with a strange sensation in the chest, heart thumping, apprehension, feeling of fainting, dizziness or weakness
- Protection of first-aiders: If potential for exposure exists refer to Section 8 for specific personal protective equipment.
- Notes to physician: Because of possible disturbances of cardiac rhythm, catecholamine drugs, such as epinephrine, that may be used in situations of emergency life support should be used with special caution.
- Suitable extinguishing media: Use extinguishing measures that are appropriate to local circumstances and the surrounding environment.
- Unsuitable extinguishing media: No applicable data available.
- Specific hazards: Cylinders are equipped with pressure and temperature relief devices, but may still rupture under fire conditions. Decomposition may occur.
- Special protective equipment for firefighters: In the event of fire, wear self-contained breathing apparatus. Wear neoprene gloves during cleaning up work after a fire.
- Further information: Cool containers/tanks with water spray.
- Pay Mode Terms: T/T (Bank Transfer)
- Port of Dispatch: Road
- Delivery Time: SAME DAY
39 Dupont Refrigerant Gas
Product Details:
Volatile | 100 % |
Vapour Pressure | 6,105 hPa at 25 Deg C (77 Deg F) |
Specific Gravity | 1.28 at 25 Deg C (77 Deg F) |
Odor | Slight, Ether-like |
Form | Liquefied Gas |
Color | Colourless |
Brand | Dupont |
pH | Neutral |
Boiling Point | -24.2 Deg C (-11.6 Deg F) |
Vapour Density | 4.5 at 25 Deg C (77 Deg F) and 1013 hPa (Air=1.0) |
Section 1. Product And Company Identification:
- Product name: DuPont™ ISCEON® 39TC® (R-423A) refrigerant
- Product Grade/Type: ASHRAE Refrigerant number designation: R-423A
- Tradename/Synonym: R-423A ISCEON® 39TC®
- MSDS Number: 130000027358
- Product Use: Refrigerant
- Manufacturer: DuPont 1007 Market Street Wilmington, DE 19898
- Product Information: 1-800-441-7515 (outside the U.S. 1-302-774-1000)
- Medical Emergency: 1-800-441-3637 (outside the U.S. 1-302-774-1139)
- Transport Emergency: CHEMTREC: 1-800-424-9300 (outside the U.S. 1-703-527-3887).
Section 2. Hazards Identification:
Emergency Overview Misuse or intentional inhalation abuse may lead to death without warning. Vapours are heavier than air and can cause suffocation by reducing oxygen available for breathing. Rapid evaporation of the liquid may cause frostbite.
- Potential Health Effects Skin: Contact with liquid or refrigerated gas can cause cold burns and frostbite. May cause skin irritation. May cause: Discomfort, itching, redness, or swelling.
- Eyes: Contact with liquid or refrigerated gas can cause cold burns and frostbite. May cause eye irritation. May cause: tearing, Redness, Discomfort.
Section 4. First Aid Measures:
- Skin contact: In case of contact, immediately flush skin with plenty of water for at least 15 minutes. Take off all contaminated clothing immediately. Consult a physician. Wash contaminated clothing before re-use. Treat for frostbite if necessary by gently warming affected area.
- Eye contact: In case of contact, immediately flush eyes with plenty of water for at least 15 minutes. Consult a physician if necessary.
- Inhalation: Remove from exposure, lie down. Move to fresh air. Keep patient warm and at rest. Artificial respiration and/or oxygen may be necessary. Consult a physician.
- Ingestion: Is not considered a potential route of exposure.
- General advice: Never give anything by mouth to an unconscious person. When symptoms persist or in all cases of doubt seek medical advice.
- Notes to physician: Because of possible disturbances of cardiac rhythm, catecholamine drugs, such as epinephrine, that may be used in situations of emergency life support should be used with special caution.
Section 5. Firefighting Measures:
- Flammable Properties Flash point: does not flash.
- Lower explosion limit: Method: None per ASTM E681
- Upper explosion limit: Method: None per ASTM E681
- Fire and Explosion Hazard: Cylinders are equipped with pressure and temperature relief devices, but may still rupture under fire conditions. Decomposition may occur. Contact of welding or soldering torch flame with high concentrations of refrigerant can result in visible changes in the size and colour of the torch flame. This flame effect will only occur in concentrations of product well above the recommended exposure limit. Therefore stop all work and ventilate to disperse refrigerant vapors from the work area before using any open flames. This substance is not flammable in air at temperatures up to 100 deg. C (212 deg. F) at atmospheric pressure. However, mixtures of this substance with high concentrations of air at elevated pressure and/or temperature can become combustible in the presence of an ignition source. This substance can also become combustible in an oxygen enriched environment (oxygen concentrations greater than that in air).
- Pay Mode Terms: T/T (Bank Transfer)
- Port of Dispatch: road
- Delivery Time: immedate
- Packaging Details: cylinder